Lead Acid Battery Chargers, Switchmode-Type
      High quality and low prices
Visit our Showroom for pictures
Click on a Model number or Series number below to get more 
      detailed information on that Charger Model number or Series number
(Listed in order of "No. of Cells", ascending, in each Category)

Catalog Models of Lead Acid Switchmode-Type Battery Chargers:
Click on the"selections" immediately below to move to the selected types on this same page.
Type
Output Wattage
Desktop Lead-Acid Battery Chargers, Switch-Mode Regulated, Plastic Case FR
47
Open-Frame Lead-Acid Battery Chargers, Switch-Mode Regulated, Case PD
47
Desktop Lead-Acid Battery Chargers, Switch-Mode Regulated, Plastic Case GY
100
Open-Frame Lead-Acid Battery Chargers, Switch-Mode Regulated, Case PE
100
Desktop Lead-Acid Battery Chargers, Switch-Mode Regulated, Metal Case TA (internal fan)
170
Enclosed Lead-Acid Battery Chargers, Switch-Mode Regulated, Metal Case TA (internal fan)
170
Enclosed Lead-Acid Battery Chargers, Switch-Mode Regulated, Metal Case TD (internal fan)
(product in development)
800
Rain-Resistant, Enclosed Lead-Acid Battery Chargers, Switch-Mode Regulated, Metal Case VR (internal fan)
(product in development)
1175
Rain-Resistant, Enclosed Lead-Acid Battery Chargers, Switch-Mode Regulated, Metal Case VS (internal fan)
(product in development)
1175
Microprocessor-based, Enclosed Lead Acid Battery Chargers, Switch-Mode Regulated, Various Charge Algorithms,
Rain-Resistant Metal Case VS (internal fan)
(product in development)
1175

Desktop Lead Acid Battery Chargers, Switchmode Regulated, 
Plastic Case FR, 47 Watt

Click here to see pictures of these chargers (120 sec load time)

Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector , and with 2-conductor power output cable with a connector on its end to connect to a customer-furnished mating connector leading to battery system (or with other terminations such as alligator clips, etc.; note that an in-line fuse  is needed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  2-conductor cable can be provided with a connector on its end to connect to a customer-furnished mating connector leading to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4DB1FR
13.8 v/1.6A,
FR
Float
1.6AH @ C/1; 3.2aH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
6 cells
12
S4DB1FR
13.8 v/3.2A,
FR
Float
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power/
Optional 4-wire for addl temp sense
6 cells
12
S4DB2FR
14.4v/1.6A,
FR
3-stage
1.6AH @ C/1; 3.2aH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
6 cells
12
S4DB2FR
14.4v/3.2A,
FR
3-stage
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
6 cells
12
S4DB2FR
14.7v/1.6A,
FR
3-stage
1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
6cells
12
S4DB2FR
14.7v/3.2A,
FR
3-stage
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
12 cells
24
S4DB1FR
27.6V/0.8A,
FR
Float
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
12 cells
24
S4DB1FR
27.6V/1.6A,
FR
Float
1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
12 cells
24
S4DB2FR
28.8V/0.8A,
FR
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
12 cells
24
S4DB2FR
28.8V/1.6A,
FR
3-stage 1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
12 cells
24
S4DB2FR
29.4V/0.8A,
FR
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
12 cells
24
S4DB2FR
29.4V/1.6A,
FR
3-stage 1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
18 cells
36
S4DB1FR
41.4v/0.6A,
FR
Float
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
18 cells
36
S4DB1FR
41.4v/1.2A,
FR
Float
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
18 cells
36
S4DB2FR
43.2v/0.6A,
FR
3-stage
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
18 cells
36
S4DB2FR
43.2v/1.2A,
FR
3-stage
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
18 cells
36
S4DB2FR
44.1v/0.6A,
FR
3-stage
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
18 cells
36
S4DB2FR
44.1v/1.2A,
FR
3-stage
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
24 cells
48
S4DB1FR
55.2v/0.8A,
FR
Float
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
24 cells
48
S4DB1FR
55.2v/0.8A,
FR
Float
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
24 cells
48
S4DB2FR
57.6v/0.8A,
FR
3-stage
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12
90 to 264 (universal)
Switch-mode/
Electronic
24 cells
48
S4DB2FR
57.6v/0.8A,
FR
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
24 cells
48
S4DB2FR
58.8v/0.8A,
FR
3-stage
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12
90 to 264 (universal)
Switch-mode/
Electronic
24 cells
48
S4DB2FR
58.8v/0.8A,
FR
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
 
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections

Open-Frame Lead Acid Battery Chargers, Switchmode Regulated, 
Case Size PD, 47 Watt

Click here to see pictures of these chargers (120 sec load time)

Back to top, "Catalog Models" selections
Charger models of open-frame type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with three (3) 0.11" Fastons for input wire connections to the charger unit, and with two (2) 0.11" Fastons for output wire connections to the battery system (note that an in-line fuse  needs to be customer-installed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  connection to sense battery system temperature can be made using two (2) 0.11" Fastons on the charger unit for connecting two (2) wires to connect to a diode (sensor) located next to the batteries to sense the battery system temperature.
Size:  6.20" long x 2.96" wide x 1.94" high.  Weight:   1.0 lbs. (approx.) 

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output
Connections
6 cells
12
S4NB1PD
13.8 v/1.6A,
PD
Float
1.6AH @ C/1; 3.2aH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6 cells
12
S4NB1PD
13.8 v/3.2A,
PD
Float
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6 cells
12
S4NB2PD
14.4v/1.6A,
PD
3-stage
1.6AH @ C/1; 3.2aH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6 cells
12
S4NB2PD
14.4v/3.2A,
PD
3-stage
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6 cells
12
S4NB2PD
14.7v/1.6A,
PD
3-stage
1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6cells
12
S4NB2PD
14.7v/3.2A,
PD
3-stage
3.2AH @ C/1; 6.4AH @ C/2; 9.6AH @ C/3; 12.8AH @ C/4; 16.0AH @ C/5; 19.2AH @ C/6; 22.4AH @ C/7; 25.6AH @ C/8; 32.0AH @C/10; 38.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB1PD
27.6V/0.8A,
PD
Float
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB1PD
27.6V/1.6A,
PD
Float
1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2PD
28.8V/0.8A,
PD
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2PD
28.8V/1.6A,
PD
3-stage 1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2PD
29.4V/0.8A,
PD
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2PD
29.4V/1.6A,
PD
3-stage 1.6AH @ C/1; 3.2AH @ C/2; 4.8AH @ C/3; 6.4AH @ C/4; 8.0AH @ C/5; 9.6AH @ C/6; 11.2AH @ C/7; 12.8AH @ C/8; 16.0AH @C/10; 19.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB1PD
41.4v/0.6A,
PD
Float
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB1PD
41.4v/1.2A,
PD
Float
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2PD
43.2v/0.6A,
PD
3-stage
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2PD
43.2v/1.2A,
PD
3-stage
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2PD
44.1v/0.6A,
PD
3-stage
0.6AH @ C/1; 1.2AH @ C/2; 1.8AH @ C/3; 2.4AH @ C/4; 3.0AH @ C/5; 3.6AH @ C/6; 4.2AH @ C/7; 4.8AH @ C/8; 6.0AH @ C/10; 7.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2PD
44.1v/1.2A,
PD
3-stage
1.2AH @ C/1; 2.4AH @ C/2; 3.6AH @ C/3; 4.8AH @ C/4; 6.0AH @ C/5; 7.2AH @ C/6; 8.4AH @ C/7; 9.6AH @ C/8; 12.0AH @ C/10; 14.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB1PD
55.2v/0.8A,
PD
Float
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB1PD
55.2v/0.8A,
PD
Float
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2PD
57.6v/0.8A,
PD
3-stage
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2PD
57.6v/0.8A,
PD
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2PD
58.8v/0.8A,
PD
3-stage
0.4AH @ C/1; 0.8AH @ C/2; 1.2AH @ C/3; 1.6AH @ C/4; 2.0AH @ C/5; 2.4AH @ C/6; 2.8AH @ C/7; 3.2AH @ C/8; 4.0AH @C/10; 4.8AH @ C/12
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2PD
58.8v/0.8A,
PD
3-stage
0.8AH @ C/1; 1.6AH @ C/2; 2.4AH @ C/3; 3.2AH @ C/4; 4.0AH @ C/5; 4.8AH @ C/6; 5.6AH @ C/7; 6.4AH @ C/8; 8.0AH @C/10; 9.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections

Desktop Lead Acid Battery Chargers, Switchmode Regulated, 
Plastic Case GY, 100 Watt

Click here to see pictures of these chargers (120 sec load time)

Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector , and with 2-conductor power output cable with a connector on its end to connect to a customer-furnished mating connector leading to battery system (or with other terminations such as alligator clips, etc.; note that an in-line fuse  is needed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  2-conductor cable can be provided with a connector on its end to connect to a customer-furnished mating connector leading to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4DB1.1GY
13.8 v/6.0A,
GY
Float
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6 cells
12
S4DB2.1GY
14.4v/6.0A,
GY
3-stage
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6cells
12
S4DB2.1GY
14.7v/6.0A,
GY
3-stage
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4DB1.1GY
27.6V/3.4A,
GY
Float
3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
12 cells
24
S4DB2.1GY
28.8V/3.4A,
GY
3-stage 3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4DB2.1GY
29.4V/3.4A,
GY
3-stage 3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
18 cells
36
S4DB1.1GY
41.4v/2.3A,
GY
Float
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4DB2.1GY
43.2v/2.3A,
GY
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4DB2.1GY
44.1v/2.3A,
GY
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4DB1.1GY
55.2v/1.7A,
GY
Float
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4DB2.1GY
57.6v/1.7A,
GY
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
24 cells
48
S4DB2.1GY
58.8v/1.7A,
GY
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections

Open-Frame Lead Acid Battery Chargers, Switchmode Regulated, 
Case Size PE, 100 Watt

Click here to see pictures of these chargers (120 sec load time)

Back to top, "Catalog Models" selections
Charger models of open-frame type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with three (3) 0.25" Fastons for input wire connections to the charger unit, and with two (2) 0.25" Fastons for output wire connections to the battery system (note that an in-line fuse  needs to be customer-installed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  connection to sense battery system temperature can be made using two (2) 0.11" Fastons on the charger unit for connecting two (2) wires to connect to a thermistor (sensor) located next to the batteries to sense the battery system temperature.
Size:  6.50" long x 3.30" wide x 1.94" high.             Weight:   1.5 lbs. (approx.)

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.

No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4NB1.1PE
13.8 v/6.0A,
PE
Float
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6 cells
12
S4NB2.1PE
14.4v/6.0A,
PE
3-stage
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
6cells
12
S4NB2.1PE
14.7v/6.0A,
PE
3-stage
6.0AH @ C/1; 12AH @ C/2; 18AH @ C/3; 24AH @ C/4; 30AH @ C/5; 36AH @ C/6; 42AH @ C/7; 48AH @ C/8; 60AH @C/10; 72AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB1.1PE
27.6V/3.4A,
PE
Float
3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2.1PE
28.8V/3.4A,
PE
3-stage 3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
12 cells
24
S4NB2.1PE
29.4V/3.4A,
PE
3-stage 3.4AH @ C/1; 6.8AH @ C/2; 10.2AH @ C/3; 13.6AH @ C/4; 17.0AH @ C/5; 20.4AH @ C/6; 23.8AH @ C/7; 27.2AH @ C/8; 34.0AH @ C/10; 40.8AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB1.1PE
41.4v/2.3A,
PE
Float
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2.1PE
43.2v/2.3A,
PE
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
18 cells
36
S4NB2.1PE
44.1v/2.3A,
PE
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB1.1PE
55.2v/1.7A,
PE
Float
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2.1PE
57.6v/1.7A,
PE
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
24 cells
48
S4NB2.1PE
58.8v/1.7A,
PE
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
See description above
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections


Desktop Lead Acid Battery Chargers, Switchmode Regulated, 
Metal Case TA, 170 watt (internal fan)

Click here to see pictures of these chargers (120 sec load time)

Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector , and with 2-conductor power output cable with a connector on its end to connect to a customer-furnished mating connector leading to battery system (or with other terminations such as alligator clips, etc.; note that an in-line fuse  is needed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  2-conductor cable can be provided with a connector on its end to connect to a customer-furnished mating connector leading to a thermistor to sense the battery system temperature.
Size:  7.87" long x 3.94" wide x 3.15" high.         Weight:  3.25 lbs. (approx.) 

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4DB1.1TA
13.8 v/11.5A,
TA
Float
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6 cells
12
S4DB2.1TA
14.4v/11.5A,
TA
3-stage
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6cells
12
S4DB2.1TA
14.7v/11.5A,
TA
3-stage
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4DB1.1TA
27.6V/5.8A,
TA
Float
5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
12 cells
24
S4DB2.1TA
28.8V/5.8A,
TA
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4DB2.1TA
29.4V/5.8A,
TA
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
18 cells
36
S4DB1.1TA
41.4v/3.8A,
TA
Float
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4DB2.1TA
43.2v/3.8A,
TA
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4DB2.1TA
44.1v/3.8A,
TA
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4DB1.1TA
55.2v/2.9A,
TA
Float
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4DB2.1TA
57.6v/2.9A,
TA
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
24 cells
48
S4DB2.1TA
58.8v/2.9A,
TA
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections


Enclosed Lead Acid Battery Chargers, Switchmode Regulated, 
Metal Case TA, 170 Watt (internal fan)

Click here to see pictures of these chargers(120 sec load time)

Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector , and with 2-conductor power output cable with a connector on its end to connect to a customer-furnished mating connector leading to battery system (or with other terminations such as alligator clips, etc.; note that an in-line fuse  is needed in the (+) output lead wire somewhere between the charger and the battery system).   An optional  2-conductor cable can be provided with a connector on its end to connect to a customer-furnished mating connector leading to a thermistor to sense the battery system temperature.
Size:  7.87" long x 3.94" wide x 3.15" high.         Weight:  3.25 lbs. (approx.) 

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4EB1.1TA
13.8 v/11.5A,
TA
Float
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6 cells
12
S4EB2.1TA
14.4v/11.5A,
TA
3-stage
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
6cells
12
S4EB2.1TA
14.7v/11.5A,
TA
3-stage
11.5AH @ C/1; 23.0AH @ C/2; 34.5AH @ C/3; 46.0AH @ C/4; 57.5AH @ C/5; 68.0AH @ C/6; 80.5AH @ C/7; 92.0AH @ C/8; 115.0AH @C/10; 138.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4EB1.1TA
27.6V/5.8A,
TA
Float
5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
12 cells
24
S4EB2.1TA
28.8V/5.8A,
TA
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
12 cells
24
S4EB2.1TA
29.4V/5.8A,
TA
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
18 cells
36
S4EB1.1TA
41.4v/3.8A,
TA
Float
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4EB2.1TA
43.2v/3.8A,
TA
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
18 cells
36
S4EB2.1TA
44.1v/3.8A,
TA
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4EB1.1TA
55.2v/2.9A,
TA
Float
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power 
Optional 2-wire for temp sense
24 cells
48
S4EB2.1TA
57.6v/2.9A,
TA
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
24 cells
48
S4EB2.1TA
58.8v/2.9A,
TA
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
2-wire power
Optional 2-wire for temp sense
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections


Enclosed Lead Acid Battery Chargers, Switchmode Regulated, 
Metal Case TD, 800 Watt (internal fan)
(in development)
Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector, with Anderson Power Pole output connector on charger unit for connection of the customer furnished output power cable to connect to the battery system (note that an in-line fuse  is needed in the "plus" output lead wire somewhere between the charger and the battery system), and  with a separate DIN connector on charger unit for connection of a customer-furnished 2-wire cable to connect to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4EB1.1TD
13.8 v/40.0A,
TD
Float
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6 cells
12
S4EB2.1TD
14.4v/40.0A,
TD
3-stage
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6cells
12
S4EB2.1TD
14.7v/40.0A,
TD
3-stage
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB1.1TD
27.6V/27.0A,
TD
Float
5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1TD
28.8V/27.0A,
TD
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1TD
29.4V/27.0A,
TD
3-stage 5.8AH @ C/1; 11.6AH @ C/2; 17.4AH @ C/3; 23.2AH @ C/4; 29.0AH @ C/5; 34.8AH @ C/6; 40.6AH @ C/7; 46.4AH @ C/8; 58.0AH @ C/10; 69.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB1.1TD
41.4v/18.0A,
TD
Float
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1TD
43.2v/18.0A,
TD
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1TD
44.1v/18.0A,
TD
3-stage
2.3AH @ C/1; 4.6AH @ C/2; 6.9AH @ C/3; 9.2AH @ C/4; 11.5AH @ C/5; 13.8AH @ C/6; 16.1AH @ C/7; 18.4AH @ C/8; 23.0AH @ C/10; 27.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB1.1TD
55.2v/13.6A,
TD
Float
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1TD
57.6v/13.6A,
TD
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1TD
58.8v/13.6A,
TD
3-stage
1.7AH @ C/1; 3.4AH @ C/2; 5.4AH @ C/3; 6.8AH @ C/4; 8.5AH @ C/5; 10.2AH @ C/6; 11.9AH @ C/7; 13.6AH @ C/8; 17.0AH @ C/10; 20.4AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections


Rain-Resistant, Enclosed Lead Acid Battery Chargers, Switchmode Regulated, 
Metal Case VR, 1175 Watt (internal fan)
(in development)
Click here to see pictures of these chargers (120 sec load time)
Back to top, "Catalog Models" selections
Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector, with Anderson Power Pole output connector on charger unit for connection of the customer furnished output power cable to connect to the battery system (note that an in-line fuse  is needed in the "plus" output lead wire somewhere between the charger and the battery system), and  with a separate DIN connector on charger unit for connection of a customer-furnished 2-wire cable to connect to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4EB1.1VR
13.8 v/40.0A,
VR
Float
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6 cells
12
S4EB2.1VR
14.4v/40.0A,
VR
3-stage
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6cells
12
S4EB2.1VR
14.7v/40.0A,
VR
3-stage
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB1.1VR
27.6V/40.0A,
VR
Float
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VR
28.8V/40.0A,
VR
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VR
29.4V/40.0A,
VR
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB1.1VR
41.4v/26.6A,
VR
Float
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VR
43.2v/26.6A,
VR
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VR
44.1v/26.6A,
VR
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB1.1VR
55.2v/20.0A,
VR
Float
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VR
57.6v/20.0A,
VR
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VR
58.8v/20.0A,
VR
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB1.1VR
82.8v/13.3A,
VR
Float
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VR
86.4v/13.3A,
VR
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VR
88.2v/13.3A,
VR
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections



Rain-Resistant, Enclosed Lead Acid Battery Chargers, Switchmode Regulated, 
Metal Case VS, 1175 Watt (internal fan)
(in development)
Back to top, "Catalog Models" selections
 Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector, with Anderson Power Pole output connector on charger unit for connection of the customer furnished output power cable to connect to the battery system (note that an in-line fuse  is needed in the "plus" output lead wire somewhere between the charger and the battery system), and  with a separate DIN connector on charger unit for connection of a customer-furnished 2-wire cable to connect to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4EB1.1VS
13.8 v/45.0A,
VS
Float
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6 cells
12
S4EB2.1VS
14.4v/45.0A,
VS
3-stage
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6cells
12
S4EB2.1VS
14.7v/45.0A,
VS
3-stage
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB1.1VS
27.6V/40.0A,
VS
Float
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VS
28.8V/40.0A,
VS
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VS
29.4V/40.0A,
VS
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB1.1VS
41.4v/26.6A,
VS
Float
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VS
43.2v/26.6A,
VS
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VS
44.1v/26.6A,
VS
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB1.1VS
55.2v/20.0A,
VS
Float
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VS
57.6v/20.0A,
VS
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VS
58.8v/20.0A,
VS
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB1.1VS
82.8v/13.3A,
VS
Float
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VS
86.4v/13.3A,
VS
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VS
88.2v/13.3A,
VS
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections


Microprocessor-Based, Enclosed Lead Acid Battery Chargers, Switchmode Regulated,
Various Charge Algorithms (voltage-based lead-acid one shown below),
Rain-Resistant Metal Case VS, 1175 Watt (internal fan)
(in development)
Back to top, "Catalog Models" selections
 Charger models of type indicated in the heading above are listed in the table below with either a "Float-Charge" or "3-Step-Charge" algorithm by model selection (see Notes 1, 2, and 3 under the table), with universal input, and with IEC 320 input connector, with Anderson Power Pole output connector on charger unit for connection of the customer furnished output power cable to connect to the battery system (note that an in-line fuse  is needed in the "plus" output lead wire somewhere between the charger and the battery system), and  with a separate DIN connector on charger unit for connection of a customer-furnished 2-wire cable to connect to a thermistor to sense the battery system temperature.

Knowing your battery's (1) "number of cells and AH rating", (2) whether you want 3-stage charge or float charge, and (3) whether you want 2.45 v/cell or 2.4v/cell for "bulk and absorption phases" of 3-stage charge, then look in the table below to determine if this group of chargers have charge current ratings suited to the recharge time required for your application.
No. of Battery Cells
Battery Volts
Model or Series
Charger Output Voltage/ Current,Case Size
3-stage
or
Float
AH Ratings (approximate) of battery and the associated charge rates that are suited for Charger 
Input
Voltage
(vac)
Regulation Method/ Charge Control Method Output Cables(s)
(see Note 4)
6 cells
12
S4EB1.1VS
13.8 v/45.0A,
VS
Float
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6 cells
12
S4EB2.1VS
14.4v/45.0A,
VS
3-stage
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
6cells
12
S4EB2.1VS
14.7v/45.0A,
VS
3-stage
45.0AH @ C/1; 90.0AH @ C/2; 135.0AH @ C/3; 180.0AH @ C/4; 225.0AH @ C/5; 270.0AH @ C/6; 315.0AH @ C/7; 360.0AH @ C/8; 450.0AH @C/10; 540.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB1.1VS
27.6V/40.0A,
VS
Float
40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VS
28.8V/40.0A,
VS
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
12 cells
24
S4EB2.1VS
29.4V/40.0A,
VS
3-stage 40.0AH @ C/1; 80.0AH @ C/2; 120.0AH @ C/3; 160.0AH @ C/4; 200.0AH @ C/5; 240.0AH @ C/6; 280.0AH @ C/7; 320.0AH @ C/8; 400.0AH @C/10; 480.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB1.1VS
41.4v/26.6A,
VS
Float
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VS
43.2v/26.6A,
VS
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
18 cells
36
S4EB2.1VS
44.1v/26.6A,
VS
3-stage
26.6AH @ C/1; 53.2AH @ C/2; 79.8AH @ C/3; 106.4AH @ C/4; 133.0AH @ C/5; 158.6AH @ C/6; 186.2AH @ C/7; 212.8AH @ C/8; 266.0AH @ C/10; 319.2AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB1.1VS
55.2v/20.0A,
VS
Float
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VS
57.6v/20.0A,
VS
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
24 cells
48
S4EB2.1VS
58.8v/20.0A,
VS
3-stage
20.0AH @ C/1; 40.0AH @ C/2; 60.0AH @ C/3; 80.0AH @ C/4; 100.0AH @ C/5; 120.0AH @ C/6; 140.0AH @ C/7; 160.0AH @ C/8; 200.0AH @ C/10; 240.0AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB1.1VS
82.8v/13.3A,
VS
Float
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VS
86.4v/13.3A,
VS
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
36 cells
72
S4EB2.1VS
88.2v/13.3A,
VS
3-stage
13.3AH @ C/1; 26.6AH @ C/2; 39.9AH @ C/3; 53.2AH @ C/4; 66.5AH @ C/5; 78.8AH @ C/6; 93.1AH @ C/7; 106.4AH @ C/8; 133.0AH @ C/10; 159.6AH @ C/12.
90 to 264 (universal)
Switch-mode/
Electronic
Connectors on charger;
See Note 4
Notes: 
1)  Float charge models (also called single-mode) are for use when batteries are being used as standby in event of a power failure or when the charger is always connected to the battery during discharge.  Our standard for float charge voltage set point is 2.3v/cell.  Other set points can be offered if the 2.3v/cell is not suited to a customer's requirement.
2)  A 3-step charge algorithm consists of (1) bulk or fast charge phase, (2) absorption or taper charge phase, and (3) float or maintenance charge phase.  These 3-step charge models are for use when batteries are repeatedly being discharged and recharged; and these charger models will fully re-charge batteries more quickly without danger of overcharge.  The "bulk and absorption phases" have the same voltage set point for 3-step charger models.  We offer two different standard voltage set points for the "bulk and absorption phases", namely 2.4v/cell and 2.45v/cell as noted by separate line items in the above table for similar battery systems (ask the battery manufacturer which one is to be used).  The standard voltage set point for the float phase in the 3-step models is 2.3v/cell.
3)  The 3-step chargers are not typically connected to the battery during discharge to a connected  load.  Contact technical support for information on modifications that can be made so that 3-step chargers can be safely used to "fast charge" the battery during discharge to a connected load.
4)  Click on Accessory Items for Lead Acid Battery Chargers to go to a separate page on this web site for some accessories that can be purchased to use with the Lead Acid battery chargers.

Back to top, "Catalog Models" selections



Custom Designs of Lead Acid Battery Chargers:

If you need a custom design, ask us to quote on your special requirements!

E-mail:  sales @dynage.com

  Metal-Enclosure Types (currently under development):
 
Watts
Out
Model or Series
Charging
Algorithm
Charge Current, Amps
(by model selection)
Input
Voltage, vac
Regulation
Method
Control
Method
943 S1EB16Y 3-Step-Charge 10.7 for 72v. 90 to 132 Switch-mode Microprocessor
1250 S1EB16Y 3-Step-Charge 14.2 for 72v. 90 to 132 Switch-mode Microprocessor
2500 S4EB16Y 3-Step-Charge For 72v: 14.2 @ 120vac input, 28.4 @
240vac input.
90 to 264 (universal) Switch-mode Microprocessor